TGR6000 - 6GHz Synthesised RF Generator

Ref: TGR6000

£3,944.00 £3,549.60 excl. VAT £4,259.52 inc. VAT
Only UK orders accepted

TGR6000 - 6GHz Synthesised RF Generator

10MHz to 6000MHz frequency range
10Hz setability, +/-1ppm frequency stability
Locking to external frequency standard
-110dBm to +7dBm amplitude, 0.1dB steps
Fast stepping sweep with dwell times down to 10ms
List sweep of up to 1000 points of amplitude vs frequency
User compensation tables for specific test set-ups
Storage for 12 generator set-ups and 16 sweep lists

SPECIFICATIONS
Specifications apply after 30 minute warm-up, ambient 5°C to 40°C

FREQUENCY
Frequency Range: 10MHz to 6000MHz
Setting Resolution: 10Hz by direct keyboard entry, or in user-set increments of 10Hz to 999·999MHz by rotary control or increment–decrement keys.
Display Resolution: 10Hz
Phase Noise: 500MHz Carrier: <-110dBc/Hz (typ) @ 20kHz offset; <-120dBc/Hz (typ) @ 100kHz
3GHz Carrier: <-95dBc/Hz (typ) @ 20kHz offset; <-110dBc/Hz (typ) @ 100kHz offset
6GHz Carrier: <-89dBc/Hz (typ) @ 20kHz offset; <-104dBc/Hz (typ) @ 100kHz offset
Residual FM: Equivalent peak deviation for 300Hz to 3·4kHz B/W: 12Hz at 500MHz carrier
Settling Time:
<8ms to settle within 100Hz or 0.1ppm of final frequency, if greater.

REFERENCE FREQUENCY
Options: Internal or External (via rear panel BNC)
Internal Accuracy: +/- 1 ppm over temperature range 1 5°C to 30°C; +/- 2 ppm over 5°C to 40°C.
Internal Stability: < +/-1ppm/year ageing.
Internal Ref. Out: 10MHz from 50 Ohms, amplitude 2V pk-pk into 50 Ohms.
External Ref In: 10MHz into 50 Ohms, amplitude 2V pk-pk to 5V pk-pk.
OUTPUT LEVEL
Output Level Range: –110dBm to +7dBm (0·1µV to 500mV into 50W).
Setting Resolution: 0·1dB (or 0·01µV to 1mV) by direct keyboard entry, or in user-set increments of 0·1dB to 100dB (or 0·01µV to 100mV) by rotary control or increment–decrement keys.
Accuracy: Better than ± 2dBm.
Harmonics: <-25dBc at +7dBm. <-30dBc@levels <=0dBm 30 to 6000MHz,
<-25dBc@levels <=0dBm 10 to 30MHz
Sub-Harmonics: <3000MHz : None. >3000MHz :<–40dBc (typ) @ +7dBm.
Non-Harmonic Spurii: <–50dBc >10kHz offset 10 to 3000MHz (Note 1)
<-44dBc >10kHz offset 3000MHz to 6000MHz (Note 2).
Note 1 - <-45dBc >10kHz offset 1900–2150MHz
Note 2 - <-39dBc >10kHz offset 3800–4300MHz.
Carrier Leakage: <0.5uV generated into a 50W load by a 2 turn 25mm loop, at 25mm from the generator with output set to <-10dBm into a 50W sealed load.
Output Impedance: 50W
Output Connector: TYPE N
Reverse Protection: 50V DC
Output Switch: RF OUT on-off switch with LED for ON status.
FREQUENCY and AMPLITUDE SWEEP

Step Sweep Step frequency and/or amplitude according to a formula over a specified number of points. Formula Specifies: Frequency start/stop. Amplitude start/stop.
Dwell time at each step – programmable 0.01 to 10.000sec
Max Points: 1000
Sweep Run: Continuous or single. Sweep up or down
Step Spacing: Linear or logarithmic
Sweep Triggering: Manual, Ext. signal, timed (0.1 – 999.9sec) or via remote interface
Sync Signal: (Output Stable) available during dwell time. Programmable to be high or low
List Sweep As for Step Sweep except that a user defined table of frequency, amplitude and dwell time values defines the steps. The table can be created within the instrument or downloaded via the remote interfaces.
Max Points: 1000
List Storage: Up to 16 Sweep Lists can be stored permanently within the instrument
Point Trigger Each point in a sweep (step or list) can be subject to a trigger event rather than a dwell time.
Point Triggering Manual, Ext. signal or via remote interface.
TRIM (User Level Compensation Tables)
A table of frequency/gain pairs allows the user to modify the generator output level with respect to frequency to calibrate an entire test set up or improve the calibration of the generator alone. The table can be created within the instrument or downloaded via the remote interfaces.
Max Points: 100
OTHER INPUTS/OUTPUTS

Trig In DC coupled External Trigger Input signal used for step Sweep changes in Point Trigger mode
Input Threshold: 1.65V nominal. Trigger polarity can be set to Negative Edge or Postive Edge
Input Protection Maximum/minimum external applied voltage is +6V or –1V.
Sync Out Rear panel output SYNC signal goes to its active state when generator output frequency & level have settled within specification after a step change during Sweep. SYNC returns to inactive state at end of specified dwell period
Active Output Level: +5V (Active state set to ‘Pos’) or 0V (Active state set to ‘Neg’)
Output Impedance: 50 Ohm Minimum load impedance is also 50 Ohm
Output Protection: Output will withstand accidental short circuit to ground and applied external voltages up to +5V.
Compact half-rack 2U casing uses minimum bench space
Full remote control through RS232, USB, LAN and GPIB
Significantly lower cost than other 6GHz generators