This kit is designed to help electricians and HVAC technicians solve problems quicker. Test first for overheated electrical devices using an IR thermometer; then use the clamp meter and voltage detector to find out more about the problem
Reference to model 62:MAX
Single point offset laser sighting Best accuracy in its class: + 1% of reading Holds temperature readings for 7 seconds Dual displays shows current and MAX measurements simultaneously Backlit display for poorly lit areas Comfortable ergonomic handle with protective rubber boot for added durability Fitted carrying case Robust, award winning design Wide temperature range from -30º to 500ºC (–20º to 932ºF)
Reference to model 323 clamp meter:
New smaller size fits easily into tight places Precise measurements with 1.8% basic accuracy Resolution up to 0.01A and 0.1 V Measures AC current to 400 A Measures AC volts to 600 V Measures DC volts to 600 V Resistance measurement to 400 O Continuity for quick checking of shorts Automatic low battery indicator Display hold function All inputs are protected to EN61010-1, 600 V CAT III, UL, CSA and TüV listed
Reference to model 1AC II:
Voltbeat™ technology and continuous self-test so you always know its working Upon detection of voltage, tip glows and beeper sounds CAT IV 1000 V for added protection Expanded range: 90 V to 1000 V ac
Fluke 62 MAX+. Small in size. Big on toughness.
Dust and water-resistant: IP54 rated.
Rugged: 3-meter (9.8-foot) drop tested.
Ergonomically designed: Completely redesigned for a more natural hand fit.
Distance to spot: 12:1.
Dual lasers: Identifies area to be measured.
Large, backlit display: Makes data easier to read, even in dark areas.
True-rms ac voltage and current for accurate measurements on non-linear signals.
Resistance measurement up to 40 kΩ with continuity detection.
Slim, ergonomic design.
CAT IV 300V/CAT III 600 V safety rating.
Fluke 1AC II VoltAlert™ Voltage Detector
Voltbeat™ technology and continuous self-test, so always know it’s working.
Upon detection, tip glows and beeper sounds.
Voltage detection of 90 to 1000V ac.
CAT IV 1000 V for added protection.
Fluke C115 Soft Case
Lightweight soft case to provide optimal protection and accessory storage.
Fluke 62 MAX+ Infrared Thermometer
Specifications
Temperature Range
-30 °C to 650 °C (-22 °F to 1202 °F)
Accuracy
±1.0 °C or ±1.0% of reading, whichever is greater -10 °C to 0 °C: ±2.0 -30 °C to -10 °C: ±3.0
Response Time (95%)
Fluke 62 MAX+
<300 ms (95% of reading)
Spectral Response
8 to 14 microns
Emissivity
0.10 to 1.00
Optical Resolution
12:1 (calculated at 90% energy)
Display Resolution
0.1 °C (0.2 °F)
Repeatability of Readings
±0.5% of reading or <±0.5 °C (1 °F), whichever is greater
Power
AA battery
Battery Life
8 hours with laser and backlight on
Physical Specifications
Weight
255 g (8.99 oz)
Size
(175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches
Operating Temperature
0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature
-20 °C to 60 °C (-4 °F to 140 °F), (without battery)
Operating Humidity
10 % to 90 % RH non-condensing at 30 °C (86 °F)
Operating Altitude
2000 meters above mean sea level
Storage Altitude
12,000 meters above mean sea level
IP Rating
IP 54 per IEC 60529
Drop Test
3 meters
Vibration and Shock
IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMC
EN 61326-1:2006 EN 61326-2:2006
Standards and Agency Approval
Compliance
EN/IEC 61010-1: 2001
Laser Safety
FDA and EN 60825-1 Class II
Fluke 323 True-rms Clamp Meter
Specifications
AC current
Range
400.0 A
Accuracy
2 % ± 5 digits (45 Hz to 65 Hz) 2.5 % ± 5 digits (65 Hz to 400 Hz)
AC voltage
Range
600.0 V
Accuracy
1.5 % ± 5 digits
DC voltage
Range
600.0 V
Accuracy
1.0 % ± 5 digits
Resistance
Range
400.0 Ω/ 4000 Ω
Accuracy
1.0 % ± 5 digits
Continuity
≤ 70 Ω
AC response
True-rms
Data hold
Yes
Size
H x W x D (mm)
207 x 75 x 34
Max wire diameter
30 mm (600 MCM)
Weight
265 g
Category rating
CAT III 600 V CAT IV 300 V
Warranty
Two-year
Fluke 1AC-II VoltAlert
Specifications
Operating principle
Senses the steady state electrostatic field produced by ac voltage through insulation without requiring contact to the bare conductor. A red glow at the tip and a beeping noise (if not switched OFF) indicates the presence of voltage.
Voltage sensing ranges
Nominally, 90 V AC to 1000 V AC or 200 V AC to 1000 V AC depending on model, 45 Hz to 405 Hz; also a 20 V to 90 V control circuit model
Detector tip style
Blade or round, depending on model
Light source
One high intensity red LED
Agency Approvals
c CSA us, CE, C-Tick
Safety Rating
1000 V, CAT IV
IP Rating
IP 40
Operating Temperature
-10 °C to 50 °C
Operating humidity ranges
0 % to 95 %
(0 °C to 30 °C)
0 % to 75 %
(30 °C to 40 °C)
0 % to 45 %
(40 °C to 55 °C)
Operating Altitude
3000 meters
Batteries
2 AAA alkaline batteries included
Note: Product does not respond to random electrostatic discharge.
±1.0 °C or ±1.0% of reading, whichever is greater -10 °C to 0 °C: ±2.0 -30 °C to -10 °C: ±3.0
Response Time (95%)
Fluke 62 MAX+
<300 ms (95% of reading)
Spectral Response
8 to 14 microns
Emissivity
0.10 to 1.00
Optical Resolution
12:1 (calculated at 90% energy)
Display Resolution
0.1 °C (0.2 °F)
Repeatability of Readings
±0.5% of reading or <±0.5 °C (1 °F), whichever is greater
Power
AA battery
Battery Life
8 hours with laser and backlight on
Physical Specifications
Weight
255 g (8.99 oz)
Size
(175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches
Operating Temperature
0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature
-20 °C to 60 °C (-4 °F to 140 °F), (without battery)
Operating Humidity
10 % to 90 % RH non-condensing at 30 °C (86 °F)
Operating Altitude
2000 meters above mean sea level
Storage Altitude
12,000 meters above mean sea level
IP Rating
IP 54 per IEC 60529
Drop Test
3 meters
Vibration and Shock
IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMC
EN 61326-1:2006 EN 61326-2:2006
Standards and Agency Approval
Compliance
EN/IEC 61010-1: 2001
Laser Safety
FDA and EN 60825-1 Class II
Fluke 323 True-rms Clamp Meter
Specifications
AC current
Range
400.0 A
Accuracy
2 % ± 5 digits (45 Hz to 65 Hz) 2.5 % ± 5 digits (65 Hz to 400 Hz)
AC voltage
Range
600.0 V
Accuracy
1.5 % ± 5 digits
DC voltage
Range
600.0 V
Accuracy
1.0 % ± 5 digits
Resistance
Range
400.0 Ω/ 4000 Ω
Accuracy
1.0 % ± 5 digits
Continuity
≤ 70 Ω
AC response
True-rms
Data hold
Yes
Size
H x W x D (mm)
207 x 75 x 34
Max wire diameter
30 mm (600 MCM)
Weight
265 g
Category rating
CAT III 600 V CAT IV 300 V
Warranty
Two-year
Fluke 1AC-II VoltAlert
Specifications
Operating principle
Senses the steady state electrostatic field produced by ac voltage through insulation without requiring contact to the bare conductor. A red glow at the tip and a beeping noise (if not switched OFF) indicates the presence of voltage.
Voltage sensing ranges
Nominally, 90 V AC to 1000 V AC or 200 V AC to 1000 V AC depending on model, 45 Hz to 405 Hz; also a 20 V to 90 V control circuit model
Detector tip style
Blade or round, depending on model
Light source
One high intensity red LED
Agency Approvals
c CSA us, CE, C-Tick
Safety Rating
1000 V, CAT IV
IP Rating
IP 40
Operating Temperature
-10 °C to 50 °C
Operating humidity ranges
0 % to 95 %
(0 °C to 30 °C)
0 % to 75 %
(30 °C to 40 °C)
0 % to 45 %
(40 °C to 55 °C)
Operating Altitude
3000 meters
Batteries
2 AAA alkaline batteries included
Note: Product does not respond to random electrostatic discharge.