01428 685902 Tracklink

KL3865 HVI Pulse Integrator

Ref: TKL3865

£418.60 excl. VAT £502.32 inc. VAT
Only UK orders accepted

TKL3865 HVI Pulse Integrator for Measuring Transmitted Pulses on HVI Track Circuit

The Pulse Integrator adaptor is required for the measurement of the transmitted pulses on HVI track circuits.
The adaptor is used with a Digital Multimeter set to DC voltages and normally on the Auto range.

Care should be taken with the old version (reference 86/043906) after usage; the adaptor stores a high DC voltage which should be dissipated correctly. The new TKL1170 HVI Shunt has been developed for this purpose.

The Pulse Integrator is used in conjunction with a standard multimeter to measure the positive and negative peakvoltages of High Voltage Impulse Track Circuits. A front panel LED indicates the presence of a peak voltage, and voltages are temporarily held for verification.

TKL3865 Features and Specifications

Input Terminals 4mm plug

Output Terminals 4mm Socket

Maximum Peak Voltage 350 Volts

Dimensions mm 80x50x30

Rotary Switch Positions

  • ‘BY-PASS’ Input terminals are directly connected to the output terminals
  • ‘+’ Measurement of positive peak voltages
  • ‘-‘ Measurement of negative peak voltages
  • ‘OFF’ Discharge of internal held voltages

 

Contact us for more information about the TKL3865 HVI Pulse Integrator or other railway tools, please call 01428 685902 or email [email protected].